Large Lawn Irrigation Design: Heads, Valves, Controller

Proven Components for a 9,000 sq ft Rectangular Layout Assumptions: ≥55 PSI, ≥15–20 GPM. Use Hunter PGP rotors (20+ year track record) or upgrade to I-20 for larger nozzles. Valves: Irritrol 2400 (reliable, serviceable).

-

Water Hammer and Backflow Relief Valve Discharge

Old Toro Valve Seats Crack, Causing Pressure Spikes System off but pipes bang and backflow preventer discharges? A valve closing too fast creates water hammer. Cracked seats in 1 Toro valves are common after 12 years. Re

-

Finding Parts for a 1988 Hardie Rain Jet Valve

Specialty Irrigation Suppliers Carry Vintage Parts For a 30-year-old Hardie valve, try Ewing Irrigation, Horizon, or John Deere Landscapes. They stock legacy parts or can cross-reference. Online search may turn up NOS (n

-

Shallow Well Pumping Sand: Raise Suction or Add Separator

Sand Ingestion Usually Means Suction Is Too Deep Measure static water level and set the suction line 1–2 ft below that. If sand persists, install an inline sand separator after the pump. Avoid cloth wraps—they clog quick

-

Drought-Stressed Well: Dry or Mechanical Failure?

Don’t Assume a Dry Well—Test Pump and Electrical First A dropping retention pond suggests aquifer decline, but other failures are common: bad pump, pressure switch, tripped breaker, or wiring. Hire a well company to diag

-

Choosing a Pump for a New 70-ft Irrigation Well

Submersible Pump Sizing for Irrigation Demand For a 70-ft well with water at 14 ft, a submersible pump is best. Target 45–55 GPM for irrigation. Assuming flat terrain, a 5 HP submersible provides capacity for future expa

-

Neighbor Drainage Conflict: Redirecting Downspouts and Grading

A Michigan homeowners new house sits higher than a neighbors; rainwater flows into the neighbors yard, flooding it. A retaining wall abuts the property line. Downspouts run to the road, but the building inspector prohibi

-

Lake Pump Loses Prime Between Zones: Suction Line Leak

A 2 HP Welbilt pump with 100 suction line from lake and 50 to system lost prime during zone cycles and between zone changes. The user asked what was wrong. Prime loss between zones indicates a suction line air leak. Chec

-

Low-Cost Creek Overflow Protection: Rock-Filled Wire Baskets

A North Florida homeowner needed to levee 300 of a 3-deep creek on one side without high cost. Stone walls, cribs, and dykes were considered. Gabions—wire baskets (heavy galvanized or PVC-coated mesh) filled with rock—ar

-

Selecting Lake Pump and Pressure Tank for Irrigation

A homeowner with a lake-fed system (pump house 5 above water, 10 away; highest zone 50 up, 100 out) needed 20 GPM at 50 head for 10 rotors (1.65 GPM each) plus a garden hose. They considered 1.5 HP Flotec pumps (corrosio

-

Hunter PGP Rotors Sticking at Right Stop: Gear Damage

Twelve-year-old Hunter PGP rotors in Oregon had several replaced for geysering (known cap/seal issue). Remaining heads function but some stick at the right stop, failing to return left, causing overwatered spots. The use

-

Random Zone-Change Water Hammer in 5-Zone System

A homeowner experienced loud pipe rattling during zone changes (not on the last zone) after a bathroom remodel and blowout-port repair. Opening a faucet during transition caused water to be sucked from it. Pressure teste

-

Sudden Pressure Loss Across All Zones After Valve Repair

After a repairman fixed a stuck solenoid on one Weathermatic zone, all zones lost pressure—only gurgling. Water meter didnt spin abnormally, ruling out major mainline leak. The system is 6 years old. With no meter moveme

-

Low Sprinkler Pressure After Line Flushing: Debris at Heads

An Arizona homeowner flushed rocks from a 4-zone ¾ system but pressure remained low—heads wouldnt pop up. Manual bleed worked perfectly; adjusting the valves flow control, replacing diaphragm and solenoid didnt help. Wat

-

Valve Box Submerged in Drainage Path: Is It a Problem?

A landscaper installed valve boxes in a low spot where water collects, submerging valves and wiring. The homeowner questioned if this voids the 2-year warranty and whether relocation uphill is feasible. The landscaper cl

-

Sizing Rotors and Valves for a 5,000 sq ft Lawn

For a flat, rectangular 5,000 sq ft area (40 x 125), the number of Hunter PGP rotors and valves depends on water pressure and flow. With strong supply (70+ PSI, 15+ GPM), a minimum of 12 rotors on 3 valves (4 per valve)

-

Duplicate: Temperamental Irrigation Auto-Startup (Same as 5881)

This article is a duplicate of ID 5881, describing the same Michigan system with identical symptoms: sporadic prime loss on auto-start, manual restart works, pressure decays to zero, gauge fluctuates. The advice remains

-

Loss of Prime on Automatic Startup: Pump Suction Leak Diagnosis

A Michigan system with a 2 HP Meyer pump, two 2 PVC well points, and Hunter SRC controller lost prime during automatic morning startups but primed fine manually. Pressure dropped to 0 PSI when off, and the gauge fluctuat

-

Water Hammer at Backflow Device: Diagnosing Zone-Change Thumping

A Rapid City, SD homeowner faced loud thumping at the Watts 800M4QT backflow preventer every time the system started or switched zones. Water discharged from the bonnet, and the only reset was briefly closing the main su

-

Toro EL-6+ Timer Fails to Automate: Repair or Replace?

A new homeowner couldnt get their Toro EL-6+ controller to run automatically despite correct programming and functional manual operation. The timer kept accurate time, but scheduled starts did nothing. The unit is obsole