Flotec 3/4 HP Pump Pressure Loss: Diagnose Pump vs. Well Supply

Pump Pressure Dropped from 50+ PSI to 42 PSI Closed, 20 PSI Open

Test the pump independently:

  1. Submerge the intake pipe in a large water container.
  2. Run the pump and measure pressure.
  3. If pressure is still low → pump needs rebuild/replacement.
  4. If pressure is good → well supply or suction line is the issue.