Irrigation Controller with Indexer Delay Feature

Finding Controllers with Inter-Zone Delay for Mechanical Indexers Need modern electronic timer with pause between cycles for 6-port mechanical indexer (single solenoid feeds indexer, indexes mechanically between ports).

-

Lake-Fed Irrigation Pump Control: Relay vs. Pressure Tank Systems

Designing Pump Control for 12-Circuit Lake-Fed System Planning 1.5 HP centrifugal pump on dock (2-8 ft above lake), pushing water 8-10 ft up to 12 circuits (~12 heads each). Comparing: (1) Pump start relay from controlle

-

Single Zone Runs Uncontrollably: Three Failure Modes

Zone Stuck On: Timer, Solenoid, or Valve Issue One zone ran for hours. Only main water shutoff stopped it. Timer and valve box wiring appear normal. Three Probable Causes Timer hot terminal: Zone output relay/triac fai

-

Leaking PVC Threaded Joint: Proper Repair with Telescoping Coupling

Fixing a Bad Glue Joint at Valve Connection PVC pipe glued to threaded adapter at main shutoff valve leaks due to poor original glue job. Sealants and epoxy putty failed. Correct Repair Procedure Cut out the failed joi

-

Locating Buried Valve Boxes: Metal Detector and Witching Methods

Finding Hidden Irrigation Valves Under Sod Need to locate valve boxes buried under established lawn. Two Proven Methods Method 1: Metal Detector + Probe Use metal detector to find valve box lids (metal rim) or solenoid

-

Low Pressure on 3 of 5 Zones After Winterization

Post-Winter Startup: Three Zones Weak, Two Normal Rain Bird system professionally installed and winterized. Zones 1 & 3 work; zones 2, 4, 5 have low pressure (dribble to half-pop). Only 3 main valves for 5 zones (double

-

Broken Pump Suction Line Repair: Check Valve Identification and Replacement

Lake Intake Pipe Failure on Sta-Rite HMSF-1FL Pump Suction line shattered near pump. Complex fittings between pump and lake: white threaded coupling, larger gray fitting (cracked here), then PVC to elbows and 10-ft intak

-

ProStream Sprinkler Distance Adjustment: Tool and Technique

Adjusting Throw Distance on ProStream Sprinklers Need to reduce spray distance on ProStream lawn sprinkler heads. Adjustment Procedure Locate the small adjustment screw on top of the sprinkler, directly above the nozzl

-

Overtightened Manual Bleed Screw on Brass Valve: Repair Options

Stripped Manual Bleed Screw on Superior Brass Valve Over-tightened the flathead manual bleed screw on 10+ year old brass Superior valve. Screw spins freely, leaks at various positions. Assessment The screw threads in th

-

Zone Works Manually But Not Electrically: Valve Opening Issue

Full Flow Manual, Half Flow Electrical: Valve Diagnosis One of 3 backyard zones operates at full pressure manually but only 50% pressure electrically. Solenoid, controller, and wiring all replaced. Voltage at valve confi

-

Toro Extra Timer & Hunter PSR-22 Relay: EMF Interference Myth

Pump Relay Inconsistent Activation: Real Causes vs. EMF Claims Toro Extra timer with Hunter PSR-22 relay. Relay clicks but pump doesnt start consistently. Timer shows Mv error (excess current). Manual start often works.

-

Finding and Operating Buried Sprinkler Shutoff Valves

Locating Main Irrigation Shutoff on Unknown System New homeowner with Rain Dial Hardie system. Previous owner shut off water for sprinklers. Found water meter and green round box near street (filled with dirt). Need to l

-

Zone 2 Loses Pressure Unless Another Zone Runs Simultaneously

Bizarre Zone Behavior: Zone 2 Fails Alone But Works With Another Zone 4-zone river-fed system. Zone 2 starts with zone 1, then loses pressure after minutes. Replaced 75% of diaphragm—same. Cut diaphragm center out—same.

-

Hunter ICC Runs With Controller Unplugged: Failure Analysis

Controller Powers System Despite Being Disconnected Hunter ICC 14-zone system runs through a program with controller unplugged and battery removed. Only two zones work now. Resetting doesnt restore control. Diagnosis: C

-

New Pump Relay Not Activating: Voltage and Compatibility Check

Pump Start Relay Wont Engage from Controller New Flotec pump, digital 4-zone timer, and pump relay installed. Relay clicks when manually activated but not from timers automatic or manual start. Diagnostic Steps Measure

-

Toro Vision Controller (1990): Testing and Operation Guide

Operating a Discontinued Toro Vision Irrigation Controller New owner of property with 1990 Toro Vision model 189-66-01. No manual. Needs to test system operation. Identifying the Controller Type The Toro Vision is a hyb

-

Pro-C System Runs But No Pressure: Valve Adjustment Fix

Sprinkler Heads Barely Pop Up: Common Startup Issue Pro-C 6-zone system appears to run (controller shows operation, house pressure drops) but heads only pop slightly with minimal spray. Immediate Checks All supply valv

-

Low Pressure on Hose-Fed Sprinkler System: Pump vs. Design Fix

Analyzing Pressure Problems on Small Sprinkler Systems New 8-head front yard system (10-ft spray at 25 PSI) fed from garden hose (80 PSI static, 10 GPM). Pressure too low for proper operation. Considering pump addition o

-

Toro EL-6 Plus Zone 3 Failure: Complete Diagnostic Guide

Troubleshooting a Single Dead Zone on Toro Controller Zone 3 of 6 on a Toro EL-6+ system wont operate (auto or manual). All other zones work. System worked last season. Structured Troubleshooting Flow Test controller o

-

Single Zone Failure in 5-Zone System: Electrical Troubleshooting

Zone 4 Not Working: Systematic Diagnosis One of five zones suddenly stopped working. Other four zones operate normally. Step-by-Step Isolation Check valve wire connections — clean corrosion, replace wire nuts Verify co