A STA-Rite SLE-1 pump had a puddle underneath after use. Next day, motor runs continuously at 30 psi but pumps no water.
The puddle suggests a suction-side leak. Without prime, the pump spins air, pressure switch never satisfies, motor runs non-stop.
If no leaks found, check foot valve in lake/well for debris or failure.