Diagnosing System-Wide Pressure Loss When Irrigation Runs
Diagnosing System-Wide Pressure Loss When Irrigation Runs When turning on the irrigation system causes a dramatic pressure drop throughout the house—even after isolating sprinkler zones—the problem is likely in the main
Finding PVC Saddle Tees for Irrigation System Modifications
Finding PVC Saddle Tees for Irrigation System Modifications Saddle tees (or saddle Ts) are specialized fittings used to tap into existing PVC pipe without cutting. They can be difficult to locate at big-box stores but ar
Proper Sump Pump Discharge: Legal and Practical Solutions
Proper Sump Pump Discharge: Legal and Practical Solutions Directing sump pump water away from the foundation is critical, but the discharge method must comply with local codes and practical considerations. This article a
Diagnosing Low Water Pressure from a Well System in Arid Regions
Diagnosing Low Water Pressure from a Well System in Arid Regions In areas with limited groundwater, like western Colorado, irrigation systems often struggle with declining well performance. This article explores why pres
Eliminating Water Hammer and Pipe Thumping in Irrigation Systems
Eliminating Water Hammer and Pipe Thumping in Irrigation Systems Loud thumping or banging pipes when irrigation valves open or close is a common issue known as water hammer. This article explains the causes and solutions
Troubleshooting a Well Pump That Runs But Delivers No Water
Troubleshooting a Well Pump That Runs But Delivers No Water When a well pump operates but fails to deliver water to the system, several components could be at fault. This guide walks through systematic diagnosis based on
Managing Water Accumulation in Irrigation Valve Boxes
Managing Water Accumulation in Irrigation Valve Boxes Irrigation valve boxes that fill with water can be concerning, especially near a homes foundation. This article addresses causes, solutions, and long-term expectation
Why DIY Shallow Well Drilling Isn't Recommended for Irrigation
Why DIY Shallow Well Drilling Isnt Recommended for Irrigation Drilling a shallow well for a lawn sprinkler system may seem like a cost-saving project, but it involves significant technical challenges and risks. This arti
Diagnosing and Fixing Low Flow in Sprinkler System Valves
Diagnosing and Fixing Low Flow in Sprinkler System Valves When you have an existing sprinkler system with multiple electronically controlled valves, it can be frustrating when some zones work perfectly while others only
Generator-Powered Pump Overheats: Reduce Flow, Not Generator
Pump Overload Causes Capacitor Failure, Not Power Quality A 1.5 HP pump running 6 heads likely exceeds its design GPM, overheating the motor. The generator is fine. Reduce nozzle size on heads to lower GPM demand, or upg
Adding Heads to an Existing Zone: Check Pipe Size First
12 Heads on ½ Pipe Is Impossible—Find the Real Mainline 36 GPM through ½ pipe can’t happen. The ½ pipe likely feeds 1–2 heads off a larger main. Tap into the mainline (1 or larger) for new heads. If pressure is good, you
Shallow Well Yield Insufficient for Lawn Irrigation
6.7 GPM Well Can Only Support Drip or Few Rotors Filling 5 gal in 45 sec = 6.7 GPM. For 16,000 sq ft lawn, you’d need 20+ zones running 10+ hrs/day—impractical. Use this well for drip-irrigated beds. If you later improve
PVC Connection Failure at Pump: Stuck Zone or Bad Joint?
Melting PVC Indicates Dead-Head Pumping, Not Stuck Zone A stuck-open zone would not overheat the pump—thermal breaker trips first. More likely a zone failed to open (dead head), causing pump to run against closed dischar
Large Lawn Irrigation Design: Heads, Valves, Controller
Proven Components for a 9,000 sq ft Rectangular Layout Assumptions: ≥55 PSI, ≥15–20 GPM. Use Hunter PGP rotors (20+ year track record) or upgrade to I-20 for larger nozzles. Valves: Irritrol 2400 (reliable, serviceable).
Water Hammer and Backflow Relief Valve Discharge
Old Toro Valve Seats Crack, Causing Pressure Spikes System off but pipes bang and backflow preventer discharges? A valve closing too fast creates water hammer. Cracked seats in 1 Toro valves are common after 12 years. Re
Finding Parts for a 1988 Hardie Rain Jet Valve
Specialty Irrigation Suppliers Carry Vintage Parts For a 30-year-old Hardie valve, try Ewing Irrigation, Horizon, or John Deere Landscapes. They stock legacy parts or can cross-reference. Online search may turn up NOS (n
Shallow Well Pumping Sand: Raise Suction or Add Separator
Sand Ingestion Usually Means Suction Is Too Deep Measure static water level and set the suction line 1–2 ft below that. If sand persists, install an inline sand separator after the pump. Avoid cloth wraps—they clog quick
Drought-Stressed Well: Dry or Mechanical Failure?
Don’t Assume a Dry Well—Test Pump and Electrical First A dropping retention pond suggests aquifer decline, but other failures are common: bad pump, pressure switch, tripped breaker, or wiring. Hire a well company to diag
Choosing a Pump for a New 70-ft Irrigation Well
Submersible Pump Sizing for Irrigation Demand For a 70-ft well with water at 14 ft, a submersible pump is best. Target 45–55 GPM for irrigation. Assuming flat terrain, a 5 HP submersible provides capacity for future expa
Neighbor Drainage Conflict: Redirecting Downspouts and Grading
A Michigan homeowners new house sits higher than a neighbors; rainwater flows into the neighbors yard, flooding it. A retaining wall abuts the property line. Downspouts run to the road, but the building inspector prohibi