Hunter Pro-C (5 years): after intense monsoon, door found open, screen blank. No response to buttons, power cycle. Irrigation not running.
Controller destroyed by power surge. 5 years is typical Hunter Pro-C lifespan. They're not surge-resistant.
Label all wires before disconnecting. Match wire-for-wire on new controller. 30-minute job.
Irritrol 1200: Manual Start Not Working Despite Display Functioning
Hunter SRC Controller No Power – Replace with Rain Bird or Irritrol
Hunter Pro-C: Zone Runs Manually But Not Automatically
Hunter EC Controller Stations 1&2 Not Working: Power Surge Damage
Hunter XC Station 1 Won't Activate from Controller—Valve Works Manually
RD‑900: Three Stations Work Intermittently – Circuit Board or Wiring Fault?
Richdel 446PR Program A Fails After 2 Months – Slide Switches Worn
Hardie 446PR Display Garbled: Reset or Replace
Irritrol RD-600-INT Alternate Programs B & C Not Running Automatically
Hunter SRC "No AC" Display—Power Supply Issue