1. Home
  2. Question and Answer
  3. Houseplants
  4. Garden Articles
  5. Most Popular Plants
  6. Plant Nutrition
-

Rain Bird RC‑7BI: Manual Zone Advance Works but Auto Start Fails

The controller’s clock runs and manual zone advance waters correctly, but programmed start times don’t trigger watering. Diagnosis The controller has separate motors for timekeeping and zone advancement. The auto‑start s

-

Orbit 57606 LCD Display Fading – Can a Replacement Unit Be Wired In?

A 10‑year‑old Orbit Watermaster 57606 shows blurred top‑half digits, works only in manual. The owner bought a replacement 6‑station Orbit unit with a thick black wire and asks if it can be wired to the existing colored w

-

New Homeowner: Toro Greenkeeper System – What to Do with Valves in the Box?

After moving into a home with a Toro Greenkeeper system, the owner has programmed the controller but isn’t sure if the underground valves need manual adjustment. Answer No action is needed at the valves. They operate aut

-

Utilitech 2 HP Irrigation Pump Hums but Won’t Run – Motor or Electrical Issue?

A 2‑HP Utilitech pump hums, trips the breaker, and won’t spin even when manually started. The electrical supply is a 30 A/110 V circuit with 10‑gauge wire in conduit. Likely Causes Failed motor windings, brushes, or bea

-

Rain Bird RC1260BI: Zones 2 and 5 Cycle but Deliver No Water

The timer shows zones 2 and 5 running, but no water comes out. The owner asks how to replace the valves. Diagnosis Since two zones failed simultaneously, a wiring issue is more likely than two valves failing at once. Che

-

RJC‑6 Controller Blows Fuse, Then Loses All Power After Larger Fuse Installed

An RJC‑6 controller started blowing its fuse. The owner installed a larger fuse, after which the controller had no power at all. What Happened The original fuse blowing indicated a short circuit—usually a faulty solenoid

-

Toro Vision II Controller Repeatedly Cycles and Won’t Shut Off

A 20‑year‑old Toro Vision II 9‑station controller cycles continuously. The seasonal‑adjustment slider broke, but the issue likely stems from start‑time programming. Troubleshooting Ensure only one start‑time slide switc

-

Compatibility of ESP‑ME and ESP‑SM6 Modules with Discontinued ICC Controller

After a lightning strike damaged an ICC controller, the owner asks whether Rain Bird ESP‑ME and ESP‑SM6 modules can replace the burnt ICC module, and whether a $600 repair quote is reasonable. Answer Hunter (ICC) and Rai

-

Why Toro ECX Controller Only Programs Zones 1‑4 and Ignores 5‑6

A user with a 6‑station Toro ECX controller finds that manual operation works for all six zones, but automatic programming only allows zones 1‑4. Swapping wires confirms the valves themselves are functional. Root Cause T

-

Fixing a Nelson SmartZone Controller Stuck in Rain Sensor Suspend Mode

A homeowner reports that after a flood, their Nelson SmartZone controller displays a persistent rain‑sensor suspend symbol, even after installing a new sensor and pressing the reset button. The system runs manually but n

-

Troubleshooting a Sprinkler Zone That Shows Active but Delivers No Water

If your irrigation controller indicates that zone 1 is running but no water emerges from the sprinkler heads, follow these systematic checks to isolate the problem: 1. Verify Voltage at the Station Terminal Use a multime

-

Irritrol RD-900 Loses Programming: Power Supply Suspect

Two RD-900 units (one new exchange) revert to factory defaults (10 min/station) every few days. Battery tests good; programming holds on battery alone during power loss. Key Question Does the time of day also reset, or

-

Hardie HR6200 Shows “A1” but Station 1 Won’t Run

Controller displays “A1” (station 1 on program A) but no water flows. System sat unused for two years. Quick Checks Water supply – Ensure main irrigation shut-off is open. Valve wiring – Inspect connections at the

-

Hardie HR6100 Stuck on Station 1: Reset or Replace?

HR6100 runs station 1 continuously (display shows “1A.05”) and won’t advance to stations 2-6. Program check reads okay. Unit is ~15 years old. Reset Procedure Remove 9 V battery. Disconnect AC power for 1 minute.

-

Hunter Pro-C Master Valve Not Activating for Stations 1-3

System: Hunter Pro-C with two 3-station modules (9 stations total), PGV valves with master valve, wireless rain/freeze sensor. Master valve clicks and runs for stations 4-9 but not 1-3. Station valves 1-3 click and flow

-

Why a Weather-Matic Sprinkler System Blows Fuses

A Weather-Matic controller blows fuses. Two common culprits: Shorting solenoid – one valve’s coil draws excess current. Test by activating zones one at a time; the zone that blows the fuse has the bad solenoid. Repla

-

Troubleshooting a “Possessed” Zone Valve That Runs With Every Station

An 8-zone Irritrol system: whenever any zone runs (manual or auto), zone 7 also runs for the same duration. Disconnecting zone 7’s wire at the controller stops it. Valve 7 operates normally otherwise. No obvious wiring f

-

Rain Bird SST-440i Display Dead But Zones Run: Controller Failure

SST-440i ran at 2 AM unprogrammed. Display blank. Transformer tests good. Manual zone operation works. Whats wrong? Diagnosis If manual zone operation works, the transformer and field wiring are fine. The display/mainbo

-

Lightning Killed My KwikDial KD6: Reset or Replace?

Lightning strike. Timer screen blank, unresponsive. Transformer tests fine on voltmeter. Is there a fuse or fix? Try This First Unplug transformer for 2 minutes Reconnect power Locate reset contacts behind terminal #6

-

Rain Bird RC-7A Not Watering: Controller vs. Valve Diagnosis

Your Rain Bird RC-7A powers up and the dial advances, but no water flows. The system hasnt worked since you moved in. Follow this sequence to isolate the fault. 1. Reset and Test Controller Motion Press the reset butto

Total 1773 -Article  FirstPage PreviousPage NextPage LastPage CurrentPage:83/89  20-Article/Page Goto:1 77 78 79 80 81 82 83 84 85 86 87 88 89