Hardie Rain Dial 600: Program C Runs at 4 PM Despite Off Settings
With switch on C, backyard sprinklers run at 4 PM daily. Start times and zones set to Off. Fix Bottom “Run” switch runs ALL programs (A, B, C). Check start times 1‑3 in A, B, and C for a 4 PM entry. Remove any 4 PM start
Florida Drought Restrictions vs. Texas – Irrigation Contractor Perspective
Texas homeowner faces total irrigation ban; considers moving to Tampa/Lakeland for water access. Response Water authorities can impose any restrictions. Florida also has mismanagement; some cities prohibit irrigation. Dr
Richdel 446PR One Zone Dribbles – Check Valve Obstruction or Leak
One zone dribbles only when running; worked fine before. Troubleshooting Check valve for obstructions. To find leak, cap all heads on that zone and run until leak appears. Also check for kinked pipe from root growth.
Hardie Total Control 12‑Station Shows “SHORT” on All Stations
16‑year‑old controller shows SHORT on all stations (including unused). Power cycle and battery removal didn’t help. Master valve wire removed, same result. Possible Causes If master valve/pump start relay draws more cur
Richdel 446PR Program A Fails After 2 Months – Slide Switches Worn
Program A works manually but not auto; Program B works. Controller is 1994 vintage. Advice Slide switches wear out. Replace with Irritrol Rain Dial (6/9/12 station). Wiring: label field wires, transfer to new controller.
James Hardie RD‑600 Intermittent Shutdown – Valve or Controller?
System sometimes shuts off mid‑cycle or won’t start manually. Owner asks valve location and replacement controller. Answer Valves are in ground boxes, operated by controller. If replacement needed, use Irritrol Rain Dial
Toro Greenkeeper 212 Waters Daily Instead of Programmed Days
System waters every day despite 3‑day program. Fix Check for multiple programs/start times. Ensure only one program has one start time and correct days. Manual: https://www.thewatershed.biz/Toro_212_Greenkeeper_-_Manual.
Irritrol RD‑900 No Display – Panel Bad, Transformer Good
RD‑900 dead. 26 VAC at transformer. No 9 V battery. With new battery, display works but no zone output. Conclusion Panel is defective (battery only backs memory). Send panel to Irritrol (1‑800‑634‑8873) for repair or buy
Hunter Pro‑C Zone 5 Runs With All Zone Wires Disconnected
Zone 5 activates even with all field wires removed from controller. Test Disconnect controller power. If zone 5 stops → controller sending phantom voltage (bad). If zone 5 keeps running → valve stuck open (mechanical).
Nelson SmartZone EZ: Zone 2 Won’t Shut Off – Pump Relay or Controller Fault
Zone 2 runs continuously; only power disconnect stops it. Controller off but pump runs. Diagnosis Disconnect controller power. If pump stops → controller faulty. If pump keeps running → pump‑start relay stuck. If pump s
Irritrol RD‑600‑EXT Display Frozen at 7:00 AM – Microprocessor Issue
Display stuck at 7:00 AM, dial doesn’t change functions. Battery change no effect. Advice Microprocessor likely damaged. Contact Irritrol repair service (1‑800‑634‑8873) or replace controller.
Rain Bird ESP‑6TM to ESP‑6Si Compatibility
Owner wants to replace discontinued ESP‑6TM with ESP‑6Si. Answer Yes, ESP‑6Si is a direct replacement. Label field wires when moving them to the new controller’s terminal strip.
Hunter XC Controller Stuck on Wrong Time – Reset Procedure
Display shows incorrect time, won’t reset or program. Power cycling and reset button didn’t help. Reset Steps Remove batteries. Hold “PRG” button, press reset button in wiring compartment. Release “PRG”; display should
Hunter Pro‑C Runs at Unscheduled Times – Clear Programs B and C
Only program A set, but system runs at odd times, possibly following last year’s schedule. Fix Press reset button (behind display panel). Set all run times, days, and start times in programs B and C to zero. If phantom
Rain Bird RC‑1260BI Delay of 15‑30 Minutes Before Valve Opens in Manual
Old analog controller has long delay when manually advancing stations. Advice This model is very old (pre‑digital) and may not meet current codes. Contact Rain Bird tech support or a local distributor for repair/parts av
Hunter Pro‑C Transformer Runs Hot After Replacement – Normal or Fault?
3‑4 seconds). System works but owner concerned. Answer Transformers can run hot normally, but excessive heat may indicate a short. Contact Hunter Tech Support (760‑591‑7383) for definitive advice.
Toro TMC‑212 Zone 1 Not Working – Electrical Troubleshooting Steps
Zone 1 fails in auto and manual; other zones work. Steps Check station terminal voltage. Check zone wire continuity (ohms). Check solenoid resistance (most common failure).
Rain Bird RC‑7BI Stops Advancing After Zone 1 – Advance Motor Failed
Timer waters zone 1 then stops; manual advance works. Unplugging didn’t help. Diagnosis The zone‑advance motor has failed. The timekeeping motor still works (ticking). Repair Replace the advance motor. Contact Rain Bird
Toro TMC‑212 Manual Start Fails – Rain Drop Icon Not Flashing
Following manual, rain‑drop icon doesn’t flash, irrigation doesn’t start. Checks Ensure “Rain Delay” is off. If rain sensor connected, verify it’s not sensing moisture. Power cycle controller (unplug 1 minute). If still
Backflow Preventer Leaks After Main Water Shutoff – Poppet Seat Issue
After turning main water back on, water flows from top of backflow preventer. Fix Cycle water on/off a few times to seat poppet. If it still leaks, disassemble and clean or replace the poppet/seat assembly.