New Rain Bird System Shows "5 NOMOD": Module Not Seated
Only 4 Zones Run, Then 5 NOMOD Appears Modular controller: module for zones 5–8 not making contact. Fix Push module firmly up into controller base to seat properly.
Rain Bird ESP-6TM Won't Turn On Zones, Valves Stuck Open: Valve Mechanical Failure
Controller Buttons Work, But Sprinklers Wont Auto-Start; Main Valve On → Sprinklers Run Uncontrolled Problem is in the automatic valve, not controller. Valve stuck open (diaphragm or solenoid). Fix Find faulty valve, re
Rain Jet RJC-44 "Set Today" Stuck at 3: Disable Select-A-Day Feature
Day Setting Wont Go Past 3 Select-a-Day feature likely on, set to 3-day cycle. Fix Press Select-a-Day button, then + or - until display says OFF. Returns to 7-day week. If Still Broken Rain Jet discontinued. Replace wi
Nelson Timer E2 Code: Power Cycle with Battery Out, Need Model for Specifics
E2 Code Cleared, But Cannot Reprogram Try: remove batteries, power off 1 min, power on (batteries out), test programming. Need Model Number Provide exact Nelson model for further help.
Rain Dial 600 Starts Sprinklers in SET Mode: Panel Repairable
Malfunction: Sprinklers Activate When Switch Moved to SET Good controller — panel can be removed and repaired or replaced. Panel Removal Hinge panel open. Unplug ribbon cable. Pull panel straight out from plastic hinge
Rain Bird STP-600i Blank LCD: Screen Failed, Replace Controller
System Works But Display Blank After Power Cycle LCD screen dead. Not worth repairing. Replace With Irritrol Rain Dial or Rain Bird ESP series — both reliable, compatible.
Station 1 Runs Continuously During Other Zones: Solenoid Plunger or Diaphragm
Manual Start Zone 2/3/4, But Zone 1 Stays On Low pressure on other zones because Zone 1 valve stuck open. Check Order Solenoid plunger stuck up → clean/replace solenoid. Diaphragm failed → replace diaphragm. Guide ir
Irritrol Controller Shows "OFF 7": 7-Day Rain Delay Active
OF 7 Means Rain Delay Set for 7 Days Controller will not run any programs. Clear Delay Set bottom switch to OFF. Press minus (-) button 7 times. Display returns to current time; delay cleared.
Wilkins 720A PVB Leaks Intermittently During Cycle: Pressure Drop or Debris
Backflow Preventer Vents Water After 2–3 Days Operation Leaks only when system runs, stops after cycle ends. 4 heads/zone, worked last year. Causes Pressure drop during cycle (other water use in house, line break, too
KwikDial KD12 No Display: Reset Contacts or Replace Controller
24V at Controller, But No Display Try power cycle (1 min off). Then locate two metal contacts above terminal #6 on back. Bridge with screwdriver to reset. If No Display After Reset Microprocessor dead. Replace with Irri
Irritrol RD600 Time Blinks, Switches to OFF: Test by Disconnecting Zone 1 Wire
Manual Start Blinks Time Then Goes OFF Disconnect wire from terminal #1. Try manual start Zone 1. Still blinks/OFF → controller fault. Runs normally → fault in Zone 1 wiring or solenoid. Controller Repair Remove panel
Rain Bird Controller On But Pump Not Starting: Test PS/MV Terminal Voltage
Pump Worked 2 Weeks Ago, Rain Storm Since Check rain sensor (disable or disconnect). Then test controller output to pump start relay. Test Find wire on MV or PS terminal. Measure that terminal (+) vs C/common (-) while
Rain Bird Drip Zone Runs Constantly: Diaphragm Replacement Needed
Solenoid Replaced, No Change — Valve Stuck Open Install new diaphragm. See irrigationtutorials.com for replacement guide.
Irritrol RD1200 Eats Batteries: Panel Capacitor Failing, Repair or Replace Panel
Display Flickers, Battery Lasts ~1 Week Fault is in the panel (circuit board), likely a failing capacitor. Panel Removal Hinge panel open. Unplug ribbon cable from back. Pull panel straight out from plastic hinges. R
Irritrol RD-600 Zone 4 Dead: Solenoid or Wiring Fault, Locate Valves with Wire Tracer
Zone 4 Shows OFF Immediately on Manual Start; Problem Follows Wire Swap Junction box shown is just a manual valve with spliced wires. Automatic valves are elsewhere. Find Valves Use a wire/valve locator (rent ~$50/day o
Hunter XC-400 Erratic Cycling: Replace with Irritrol Rain Dial
10-Year-Old Controller Cycles Zone 1 and 2 Repeatedly X-Core is Hunters replacement model. But Irritrol Rain Dial is recommended — easier programming, longer life, repairable.
Toro TMC-212 LCD Partial Display: Power Cycle or Replace
Digits Partially Displayed, Hard to Read Try disconnecting power for 1 minute, then restore. If No Improvement LCD failed. Controller not repairable. Replace if malfunctioning; otherwise tolerate if still functional.
Hydro Rain 100C Works Manual But Not Auto: Check Rain Delay, Reset, Power Cycle
Auto Fails, Manual Works Only with Rain Sensor Off Ensure program has: station run times, watering days, start time. Checks Rain delay not active (press CLEAR). Press RESET, reprogram from scratch. Remove battery, powe
Irritrol RD-900 Won't Start Auto Cycle: Check Day Scheduling, Power Cycle
9-Year-Old Controller Stops Auto Start; Manual Works Verify the day is set to ON in Program A. Ensure run times are programmed. Reset Remove battery. Power off 1 minute. Power on (battery out), reprogram. If Persists
Richdel 446PRi Zone 1 Runs Only 2 Min: Slide Switch Contact Failure
Zone 1 Set for 30 Min, Runs 2 Min; Others Run Full Time Slide switch for Zone 1 not making contact. Battery behind bottom door. Controller Obsolete Richdel 446PRi not made 10+ years, poorly designed, not worth repairing