One Zone Feeding a Second Manifold – Master Valve Wiring

Front‑yard manifold valve supplies water to rear manifold. Can timer open supply valve and then rear zones sequentially? Yes – Wire as Master Valve Connect the supply valve to the controller’s MV (master valve) or PS (pu

-

Water Running Sound at One Valve When System Off – Valve Not Sealing

Water noise at one valve near main supply, but no visible leak or zone flow. Cause Valve likely not closing fully. Rebuild or replace that valve (see irrigationtutorials.com).

-

Drip Emitters on 170‑ft Line – Capacity and Converting Spray Zone to Drip

1 Irritrol valve, ½ poly, 170 ft. How many 2 GPH emitters? Also, can an existing PVC spray zone be temporarily converted to drip by capping heads and adding a pressure reducer at one head? Answers Valve delivers ~5 GPM

-

Water Hammer on 23‑Head Zone – Rebuild Valve Before Installing Arrestor

Irritrol 1 valve with 23 pop‑ups bangs once on shutoff after 20 years. Advice Try new diaphragm in existing valve. If no improvement, replace valve with a slow‑close model. Only then install water‑hammer arrestor after

-

Hardie Rain Dial: Changing Start Times from PM to AM

Owner can’t switch start time from PM to AM on Hardie Rain Dial. How‑To Hold the “+” button; the display cycles through times. Watch the AM/PM indicator – it changes from “A” to “P”. At 11:59 PM, one more press gives 12:

-

Irritrol RD‑900: Programs B and C Won’t Run Automatically

Program A runs every 3 days. Programs B and C (daily, multiple start times) only run manually. Checks Ensure bottom switch is on “Run” and dial at current time. Verify days are turned “On” for B and C, or use skip‑day =

-

Richdel R412 Day Dial Sticks at Midnight – Motor Failure

Day dial advances until midnight, then stops. Lifting the lug manually makes the system run. Diagnosis The hour‑wheel motor is failing; it lacks torque to trip the day wheel at midnight. Solution Richdel (now Irritrol) h

-

Drip Irrigation: Old Diaphragm Restricts Flow, Emitter Pressure, Backflow Preventer Maintenance

Three questions: (1) Does old diaphragm restrict flow? (2) What pressure for 1‑2 GPH emitters? (3) 30‑yr‑old Febco 765 PVB no longer drips on startup – is it causing water hammer? Answers Yes, worn diaphragms restrict f

-

Drip Irrigation Pressure Reducers Test at 60 PSI – Switch to 30 PSI?

Two 400‑ft drip lines (44 and 73 emitters at 2 GPH). After a repair, the 73‑emitter line delivers only 0.5 GPH. Senninger 20 PSI regulators read 60 PSI out when tested on house supply. Answers Regulators need flow to re

-

Thank You – Drip System Fixed, Next Challenge: Water Hammer on Grass Valve

Owner thanks for help on drip system (new diaphragm/solenoid fixed 2 GPH emitters). Now needs help with a grass valve that bangs once on shutoff. Advice Turn down the flow control on that valve to reduce closing force. I

-

Richdel 446PR Hybrid: Zone 2 Runs Continuously Even in Off Position

Zone 2 runs constantly when zone 1 runs, and stays on in “Off”. Test Unplug controller power. If zone 2 stops, controller is bad (replace). If zone 2 keeps running, valve is stuck open (rebuild or replace valve). See i

-

Hydrotek 6004 Indexing Valve: One Zone Won’t Rotate Without Tapping

One of four zones on a Hydrotek 6004 indexing valve won’t advance unless tapped. That zone has three rotor heads; others are pop‑ups. Answer Indexing valves wear internally. Rebuild kits are available. Since water flows

-

Hardie RD‑900: Valves Click but Don’t Open in Manual; Auto Works Except Chatter on #3, #6, #8

In manual/semi‑auto, all valves flash “OFF” without opening. In auto, zones run but #3 (spray), #6, #8 (drip) chatter. After battery replacement, modes work but chatter persists. Dog damaged wires. Diagnosis Chatter ind

-

Wiring a Rain Sensor into a Richdel 500PR Controller

Owner has a 2‑wire rain sensor and needs to connect it to a Richdel 500PR. Wiring Method Split the sensor wires inside the controller. Remove the common (C) wire from its terminal. Wire‑nut the common wire to one sensor

-

Water Hammer on 20‑Head Zone – Adjust Flow Control Before Replacing Valve

Zone with 20 spray heads bangs loudly when it shuts off. Owner considers slow‑close valve or replacing Febco 765 PVB. Advice The Febco PVB is not the cause. Turn down the flow control on the Irritrol 205TF valve to reduc

-

Reducing Water Hammer by Lowering Flow or Using Low‑Flow Nozzles

Owner has “banging” pipes when valves close. Asks if switching to water‑saving spray heads helps. Answer First, turn down the flow control on the valve. If that doesn’t help, replace nozzles with low‑flow versions (e.g.,

-

35×25 ft Lawn: Keep Spray Heads or Convert to Rotors?

Current system has 12 Toro 570 spray heads (6 per zone). Owner asks if rotors would reduce head count. Advice Keep the spray heads. They provide excellent coverage with fewer moving parts. If converting to rotors, place

Anti‑Siphon Valve Leaks – Install Inline Valve Instead

Anti‑Siphon Valve Leaks – Install Inline Valve Instead

New Orbit anti‑siphon valve leaks from the vent. Highest head is 10 ft above valve. Owner asks if a check valve at the bottom allows omitting the anti‑siphon. Answer Code requires anti‑siphon valves 18 in above the highe

Slope Irrigation Design: 35×20 ft, 45° Slope – Rotors vs. MP Rotators

Slope Irrigation Design: 35×20 ft, 45° Slope – Rotors vs. MP Rotators

Owner plans to replace a leaking anti‑siphon valve and asks about sprinkler choices for a shaded 45° slope with drought‑tolerant plants. Recommendation Use Rain Bird 1812 12‑inch pop‑up spray bodies with Hunter MP Rotato

-

ESP‑6TM Shows “PR OFF” After Fuse and Battery Replacement

Controller displays “PR OFF” despite new fuse and 3 V battery. Check Measure voltage on the two far‑left terminals marked “24 VAC” (transformer input to board). Should be 23‑26 VAC. If low, transformer is bad. If voltag