Zones 1 & 2 show 7–8 VAC + 14 VDC (should be 24 VAC, 0 DC). DC component = fried triac (AC switch) on board.
Missing ground can allow surge damage. Connect if absent.
Local irrigation shop may repair board cheaper than replacement.