Rain Dial 600 Shows "16F" - Won't Reset or Run Manual

RD-600 displays "16F" and won't reset or operate in manual mode.

Standard Reset Procedure

  1. Remove 9V battery from panel
  2. Disconnect AC power for 1 minute
  3. Reconnect AC power with battery still out
  4. Observe if display returns to normal (should show 12:00 or current time)

If Reset Fails

The panel (faceplate module) needs repair or replacement. Take it to an irrigation supply store - they can bench-test and either fix the circuit board or sell a replacement panel (~$100-120).

What "16F" Likely Means

On Rain Dial controllers, alphanumeric codes often indicate station faults. "16F" could mean Station 16 Fault (on a 12-station controller, this suggests internal logic error) or a firmware glitch. The reset clears most logic errors; persistent codes indicate hardware failure.