Manual operation: all zones work but one takes 15-20 seconds to stop after turning off. Others stop immediately.
Matt: "My guess is the solenoid or the manual activation is slightly unscrewed. Dig the valve up and tighten both. Turn clockwise. You don't need to screw them into the ground just a little until they're snug."
If unsure, provide valve model number for specific directions. A slightly loose solenoid or bleed screw lets control water bleed off slowly, delaying diaphragm closure.