1. Home
  2. Question and Answer
  3. Houseplants
  4. Garden Articles
  5. Most Popular Plants
  6. Plant Nutrition

Rain Bird ESP-6: Cycles Twice Instead of Once - Extra Start Time

Rain Bird ESP-6 runs all 4 zones correctly at 6:45 AM, then immediately repeats the cycle. Only zone 1 programmed (10 min), zones 2-4 set to 0.

Cause: Multiple Start Times Programmed

Check Start Time 2 and Start Time 3 in the programming. If you have:

  • Start Time 1: 6:45 AM
  • Start Time 2: 6:55 AM (or any time)

The controller runs the full program at each start time. After first cycle finishes (~6:55), second start time triggers immediate repeat.

Fix

  1. Enter programming mode
  2. Navigate to START TIMES
  3. Set Start Time 2 to OFF
  4. Set Start Time 3 to OFF
  5. Only Start Time 1 = 6:45 AM

If Problem Persists

  1. Power off at breaker
  2. Remove 9V battery
  3. Wait 10 minutes
  4. Reinstall battery, restore power
  5. Reprogram from scratch

If Still Fails

Controller microprocessor damaged - replace with ESP-RZX or ESP-TM2.

Copyright © www.100flowers.win Botanic Garden All Rights Reserved