If zone 1 runs fine for the first 5 minutes but then refuses to close, the valve’s flow control (the large knob on top) is probably throttled down too far. This creates insufficient pressure differential across the diaphragm to force it shut when the solenoid de-energizes.
The small knob with a slot is the manual bleed screw—leave it snug (finger-tight) during normal operation.
Mineral buildup, a small stone, or diaphragm fatigue can gradually reduce the valve’s ability to close at a restricted flow setting. The 5-minute delay corresponds to the time needed for downstream pressure to bleed down enough that the weakened spring can no longer seal the valve.
Troubleshooting a “Possessed” Zone Valve That Runs With Every Station
RC-7BI Controller Single Zone Operation: Stuck Valve Diagnosis
Hunter SRV Valve Won't Shut Off: Flush, Replace Diaphragm, or Swap Valve Internals
Sprinkler Zone Won't Run Automatically – Valve Port or Diaphragm Issue
Valve Won't Shut Off Completely – Install Inline Check Valve
Hydrotek 2120 Stuck on One Zone? Rebuild the Indexing Valve
Zone 5 Won't Fully Close: Pressure Loss to Zone 6
Rain Dial Zone Won't Shut Off After Seasonal Startup
New Valves Won't Follow Timer: Landscaper Left Flow Controls Closed
Sprinkler Zone Won't Shut Off? Troubleshoot a Stuck Valve