Symptoms: Display works, hum from Valve 1 only, manual bleed releases water at valve but no sprinkler flow. Power outage yesterday.
Each valve has a flow control stem (screw/handle on top). If turned fully clockwise (closed), valve won't open even with power. Turn counterclockwise 3–4 turns.
Bleed screw releases water from the valve body, not the sprinkler line. If flow control is closed, no water reaches heads.
Test 24 VAC at controller terminals during zone run. No voltage = controller failure. Voltage present = field wiring or valve solenoid issue.
Richdel 446 PRi Controller No Zones Activate: Common Wire and Flow Stem Checks
Rain Bird ESP-4TM with Hunter PSR-22: Pump Not Starting
Rain Bird Modular Controller Station 2 Requires Multiple Manual Starts: Valve Fault
All Sprinkler Zones Run Simultaneously: Controller or Valve Fault?
Cleaning Hunter Valves: Step-by-Step Field Procedure
Find a Broken Zone Wire: Rent a Wire Locator
Toro ECx Loses Programs A & B—Only Program C Shows
Hunter ICC: All Zones Show 26V Simultaneously—No Water Flow
Toro Zone 3 Failure: Controller Voltage Test After Valve and Pump Replacement
Hydrotek 6000 Valve Won't Cycle to Next Zone