Zone 1 Heads Don't Pop Up: Valve Flow Control or Diaphragm

Single Zone Low Pressure After DIY Spring Startup

All zones work except zone 1. Heads leak but don't pop. Prying one up gives weak spray. Other zones good. Landscaper usually does startup.

Two Valve-Centric Causes

  1. Flow control too closed – Adjust: open fully, close fully (count), open halfway.
  2. Diaphragm or port issue – Valve not opening fully. Disassemble, clean, or replace.

Since you did the startup, double-check you didn't leave a valve partially closed. Adjust flow control first.