A 2-year-old K-Rain 1522 relay buzzing loudly when system runs means the relay contacts are pitting or the coil is vibrating. This is the #1 warning sign.
While replacing, check coil voltage: should be 24 VAC from controller. If voltage is low (<20 VAC), fix that first—low voltage causes relay chatter.