A user reports an Irritrol SR1 pump relay showing 24V on the control line, but voltage drops to 1.4V across relay terminals when connected. Line voltage (240V) is present, but the pump won't energize. This classic symptom indicates a failing relay coil or contactor.
When the control circuit (24V) is connected to the relay coil, the voltage should remain near 24V if the coil is healthy. A drop to 1.4V suggests the coil is drawing excessive current due to a shorted winding or mechanical binding, or the contactor contacts are welded/pitted causing a near-short when energized.
Before replacing the relay, verify the pump motor itself isn't the issue:
Match the replacement relay exactly: 24VAC coil, 240V contact rating, same amperage rating as pump motor FLA (Full Load Amps). Consider a relay with built-in surge suppression to protect the controller from inductive spikes.