An 8-zone system with a 3 HP pond pump: pump start relay buzzes loudly only when zone 3 runs. Valve tested OK with 9V batteries.
The zone 3 hot wire is likely shorted to the pump start (MV) wire somewhere between the controller and the valves, causing the relay to chatter when zone 3 activates.
The controller's output for zone 3 may be leaking voltage to the MV terminal. Try moving zone 3 to a spare terminal (if available) or replace the controller.