Irritrol RD‑900 Flashing OFF, Dim Display – Panel Failure

Display dim/pulsing, manual cycles won’t start. Battery replacement fixed display but zones still dead.

Fix

  1. Verify AC power, check fuse.
  2. Power cycle: off, remove battery, wait 2 min, reinstall battery, power on.
  3. Factory reset: Set Programs, Program B, disconnect ribbon cable, remove battery, hold Manual, reconnect ribbon, release Manual, display 12:00 AM, reinstall battery, reprogram.
  4. If persists, call Irritrol 1‑800‑634‑8873.