Robert repaired a cracked pipe on zone 3, then found no zones would turn on. Could be backflow device or pump issue.
If the pump lost prime during repair work, it won't deliver water. Reprime, check suction line for air leaks (even tiny ones), and verify foot valve holds water. A single air leak prevents priming.
Confirm water source and pump type. Then systematically verify: power to pump, pump prime, suction integrity, mainline valves open, controller sending 24VAC to valves. Reply with details for further guidance.