When nothing runs automatically or manually—but valves work manually at the solenoid—the fault is in the control circuit: controller output, field wiring, or solenoids. Check in this order.
Some controllers have a replaceable fuse (glass or PTC). If blown, replace and test. If it blows again, you have a field short (see Step 2).
You mentioned rain sensor is "off." Verify: sensor switch on controller set to "bypass" or "off," not "active." Some sensors have a manual override spindle—ensure it's not engaged.
If one zone works manually at controller but others don't, compare wiring. The working zone proves controller output and common wire are good. Focus on the non-working zones' hot wires and solenoids.