Toro DDC-6 (4-5 years old): screen blank with AC adapter. Replaced battery - works on battery alone, but with AC connected, weird symbols appear then blank. Reset didn't help.
Check transformer output with multimeter on VAC:
Battery powers only the microprocessor/memory (low current). AC transformer powers the microprocessor PLUS valve output drivers (higher current). A failing transformer or controller input circuit can't handle the load.
Consider Rain Bird ESP-RZX or Irritrol Rain Dial - more reliable than Toro DDC series.