The TMC-212 displays "FUSE" with a station number when it detects excessive current draw (short) on that station's circuit. It bypasses the faulty station but continues running others. If the pump/master valve circuit faults, it shows "MV" and "FUSE" alternately and halts the program.
This appears to be a corrupted display or secondary fault indicator—often seen after power surges. The installer's note about sensitivity to surges is accurate; the TMC-212 benefits from a dedicated 120 V circuit with surge protection.
If faults recur after clearing, the controller's output triacs may be damaged from prior surges—replacement is advised.