Hardie HR 6200: One Station Has Pressure But No Spray

Troubleshooting a Hardie HR 6200 Zone with Flow but No Head Operation

On a 5-station Hardie HR 6200 system, station 1 makes a loud pressure sound but no water exits the heads. Other stations work fine. The owner lacks a manual.

Two Likely Causes

  1. Leak near the valve – Water escapes before reaching the heads. Check the valve box and lateral line for a break.
  2. Valve flow control closed too far – The valve may be partially shut. Adjust it:

Adjustment procedure: Turn the knob on top all the way open, then all the way closed (count turns), then open halfway.

If adjustment doesn't help, inspect the valve diaphragm and ports for debris. A manual for the HR 6200 may be found online by searching the model number.