The Hydrotek 2120 uses a mechanical indexing (rotating) valve to switch zones. If it's stuck on one zone, the indexing valve is seized — not the timer.
Each time the pump starts, water pressure rotates the valve to the next zone. If the valve doesn't rotate, the same zone runs repeatedly.
We don't service Hydrotek, but any irrigation shop can source kits. This is a common, well-understood failure mode.