If your Hardie HR-6100 has confirmed power to the unit, fuse is good, but display stays blank, the internal transformer has failed.
Hardie HR-6100 transformers are often soldered on the main board. Replacing the whole board costs more than a new controller. An external plug-in transformer bypasses the dead internal one.
Mount the new transformer in a weatherproof electrical box near the controller. Run low-voltage wire (18 AWG) to the controller terminals. Use wire nuts and seal with electrical tape.
Reply with your location and I'll link a specific product.
James Hardie Rain Dial 1994 No Display—Power and Ribbon Checks
Adding Stations to a James Hardie (Irritrol) Controller: Understanding Station Limits
Programming Hardie Rain Dial for Weekly Watering Schedule
James Hardie Touch Command LX II Lost Stations After Power Outage
James Hardie HR-6100 No Power: Transformer Replacement Guide
Hardie Rain Dial RD-600 Blank Screen After Power Outage: Likely Lightning Damage