James Hardie Rain Dial 1994 No Display—Power and Ribbon Checks

Rain Dial by Hardie (1994, 27631): no display, plugged in, new battery. Lawn dying.

Checks

  1. Breaker panel: power to outlet (indoor) or junction box (outdoor)?
  2. Ribbon cables secured? (Inside front panel)
  3. Fuse visible behind front panel? (Some models)
  4. Fresh battery should show time — if not, controller damaged

Water Damage Risk

If door left open during rain → logic board (in front panel) likely destroyed.

Manual

coastwaterworks.com → Irritrol/Hardie → Rain Dial.