Any controller can accept a rain sensor by interrupting the common wire to the valves.
When rain exceeds the set threshold (e.g., ¼"), the sensor opens the circuit, breaking common continuity. The controller still "runs" but no voltage reaches the valves.
No other wiring method is needed for basic rain shutoff.
Richdel 508PR Rain Sensor Override for Winterization: Bypass Common Wire
Fixing a Nelson SmartZone Controller Stuck in Rain Sensor Suspend Mode
Toro Vision II Controller Repeatedly Cycles and Won’t Shut Off
Rain Bird PC-106PS: Dog Chewed Wires, Need Reconnection Guide
Rain Bird ESP Modular Rain Sensor Won’t Reset – Moisture Still Present
Toro Vision II Plus Runs Every Cycle Twice: Seasonal Adjust or Extra Start Time
Hydro Rain HR 6100 Wiring: Identifying Loose Common and Station Wires
Wiring a Rain Sensor into a Richdel 500PR Controller
Toro TMC‑212 Manual Start Fails – Rain Drop Icon Not Flashing
Toro Vision I F2 Fuse Blows Instantly – Transformer or Controller
Adding a Wireless Rain Sensor to Hardie HHA 11272 Controller