One of 3 backyard zones operates at full pressure manually but only 50% pressure electrically. Solenoid, controller, and wiring all replaced. Voltage at valve confirmed.
The solenoid provides insufficient force to fully lift the diaphragm against system pressure, but manual bleed (which vents the upper chamber directly) works perfectly.
This is a known failure mode on older valves where the solenoid's magnetic force degrades or the diaphragm loses elasticity.