After repairing root-cracked PVC near a 3-valve manifold on a Hardie HD 15 system, all 4 zones run continuously even in manual single-zone mode.
Excavation likely nicked or severed control wires between the controller and valves. This creates short circuits between zone wires and common, energizing all solenoids simultaneously.
If wires are damaged underground, consider running new control wire in conduit rather than repairing multiple underground splices.