After a severe storm, two zones run simultaneously and continuously. Disconnecting their wires at the controller stops them.
The controller's output triacs for those zones are likely shorted closed by a voltage surge.
Replace the controller. Verify all wire connections at the controller and valves are tight and corrosion-free before installing the new unit.
Install a plug-in surge suppressor on the controller's 120 V outlet and consider a low-voltage surge arrester on the common wire.
Irritrol RD-600 Intermittent Operation: Cold Solder Joints on Circuit Board
Programming a Rain Jet Controller: Get the Manual First
Hardie TC-800 Adding 5th Zone to Schedule—Program Structure
Sprinkler and Drip System Not Activating: Master Valve or Main Supply Issue
Sprinkler Controller Blank Screen After Electrical Work: Power Surge Recovery
Winterizing a Hunter Sprinkler System: Blow-Out Method with Air Compressor
Sprinkler on Well Without Tank: Use Hose-End Impact Sprinklers
Hardie Controller Runs Continuously – Multiple Start Times Programmed
Control Valve Won't Shut Off – Replace Valve After Diaphragm Fails
Identifying Sprinkler System Brand Without a Controller