When a zone valve stays open after the controller turns it off—and tightening the bonnet doesn't help—the solenoid plunger is likely stuck in the "up" (open) position, or the diaphragm is torn.
Solenoid failure is the most common cause of "valve won't close." It's the easiest and cheapest part to replace. Diaphragm tears usually cause weeping (slow leak), not full-open failure.
Pro tip: When reinstalling the solenoid, don't overtighten—snug + ¼ turn. Overtightening distorts the plunger bore.