On a 6-zone system, zone 1 shows low pressure and causes the pump to cycle on/off every 2–4 seconds. Other zones work fine. Opening the valve's flow control (large knob) and bleed screw (small knob) improved flow, but then zone 1 wouldn't shut off when zone 2 started.
The bleed screw releases the control water that holds the diaphragm closed. If the valve operates only with the bleed screw open, the solenoid isn't fully releasing that control water—usually because debris is blocking the solenoid's dump port or the solenoid plunger is stuck.
Internal contamination is common after pipe repairs or when new pipe debris enters the system.