A Hunter EC 6-station indoor controller skips stations 1 and 2 in auto mode, jumping directly to station 3. Valves 1 and 2 are clean and functional. Wiring swapped with working stations—no change. Recent power failures occurred. Controller reset attempted.
Since valves and wiring test good (swapped with working zones), and controller reset didn't help, the issue is almost certainly damaged output circuitry for stations 1 and 2 on the controller board. Power surges during outages commonly damage triac outputs for specific stations.
Hunter Pro-C or HCC (WiFi) are current equivalents. Rain Bird ESP-ME3 or ESP-TM2 are also excellent alternatives. All offer better surge resistance than older models.