Zones 2&3 run together on an 8-zone system. Wire-swapping tests at controller and solenoid prove controller terminals 2&3 are internally bridged.
Controller output drivers for stations 2&3 are shorted together. Valves and field wires are good.
Your systematic testing nailed it. Controller is the culprit.