Common (C) terminal: One wire connects to all valve solenoids (one wire each).
Stations 1–6: Each station wire runs to one valve's other solenoid wire.
After rewiring, one Richdel 713DPR valve stays open and leaks between body halves.
irrigationtutorials.com shows diaphragm replacement.
If the body is cracked, replace the entire valve top (bonnet + solenoid + diaphragm) as a unit.
Pump Runs But No Water: Green Wire Mystery in Valve Box
Leaking Sprinkler Heads: Valve Diaphragm or Low-Head Drainage?
Reducing Excessive Pressure in a Drip Irrigation System: Install a Pressure Regulator
Wireless Remote Flow Control Valves for Irrigation: Options and Limitations
Control Valve Won't Shut Off: Stuck Solenoid or Diaphragm
Diagnosing a Dead Zone in a 6-Zone In-Ground Sprinkler System
Hydro Rain HR 6100 Wiring: Identifying Loose Common and Station Wires
Hardie Total Control 12‑Station Shows “SHORT” on All Stations
Toro Vision Series I Blows Fuses After Storm: Replace Controller
Nelson EZ Jr Controller: All Valves Pulse On Then One Stays On – Wiring Error
Adding a Wireless Rain Sensor to Hardie HHA 11272 Controller
Hardie Controller Displaying Random Characters: Reset Procedure
Copyright © www.100flowers.win Botanic Garden All Rights Reserved