If zone 1 runs continuously even with controller OFF, the valve is stuck open — usually due to debris in the diaphragm or a failed diaphragm on a Rain Bird DV100.
Ensure the external bleed screw (on top of solenoid) is fully tightened. If loose, the valve cannot close.
Replace with genuine Rain Bird DV100 diaphragm kit. Available at irrigation supply or big-box stores.
Install a wye strainer upstream if water has sediment — prevents recurring issues.