You added a sprinkler head, capped the others on that zone. The new head works when the timer runs—but won't shut off when the zone closes. Even turning off the timer doesn't stop it. Only closing the main water supply stops the flow.
The automatic valve for that zone is stuck open. Most likely cause: a torn or debris-blocked diaphragm. With fewer heads (less flow), the valve can't generate enough pressure differential to close.
Detailed rebuild guides at irrigationtutorials.com. It's a 20-minute, $10 fix. Don't replace the whole valve unless the body is cracked.
Finding Replacement Heads for Vintage Rain Jet Roof Sprinklers
Adjust Nelson 6000 Rotor: See Signature Control Systems Guide
Selecting Rotary Heads and Pipe Sizing for a 110' x 100' Front Lawn
Rain Jet Timer "Bad 4" Error: Capped Zone Fix
Why One Sprinkler Zone Stopped Working Overnight
Two Heads Dry on One Zone: Valve, Pipe, or Clog
K2 Sprinkler Adjustment: Center Slot Sets Left Stop, Side Slot Unknown
Rain Bird EC Controller Zone 8 Blanks Screen: Troubleshooting Steps
Dead Grass Around Sprinkler Heads – Adjust Flow or Increase Run Time
Adjusting Toro Vision 1 Rotor Sprinkler Head Arc
14 Heads on One Zone: Pressure Drop Proves Too Many Heads
Orbit Tripod Sprinkler Head Adjustment for Indoor Arena