When manually running zone 8 on a Rain Bird EC causes the display to go blank and no water flows—but zone 1 works—the issue is likely a short in zone 8's solenoid or wiring that trips the controller's protection.
EC models detect high/low current faults. A shorted solenoid draws excess current, causing controller to reset (blank screen). This protects the output triac.
Start with the reset—it clears latch-up states. Then isolate zone 8 circuit.