Waterfall Tubing Leaking: UV Damage or Defect?

Flexible rubber tubing (pond to waterfall top) develops pinhole leaks after 5 days off. Cause?

Primary Suspect: UV Degradation

Sunlight (UV) breaks down rubber/plastic polymers → embrittlement → microcracks → leaks. 5 days off = no cooling flow → tubing heated in sun → accelerated damage.

Other Causes

  • Manufacturing defect (thin spots).
  • Chemical exposure (algaecide, chlorine).
  • Rodent chewing (check for teeth marks).
  • Kink stress from settling.

Fix & Prevention

  1. Replace: Use UV-resistant tubing (EPDM, reinforced PVC, kink-free).
  2. Bury It: 6–12" deep. Best protection from UV, freeze, rodents.
  3. Sleeve It: Run inside larger PVC conduit if burial impossible.
  4. Shade: Plantings or cover over exposed runs.

Don't patch pinholes. They multiply. Replace the run properly.