After fixing a suction line check valve leak, your pump maxes at 20 psi (switch 20/40). You suspect a collapsed well—but it's likely a persistent air leak.
A shallow well pump (jet pump) develops ~20–25 psi suction max—insufficient to collapse a well casing or screen. Well screens plug slowly over years, not days.
If no air leaks found, backflush the well: connect a pump to the well head and push water DOWN through the screen to dislodge sediment. A pressure washer can work but risks damaging the screen. Better: a dedicated well surging tool or a contractor with a surge block.
Well screens don't clog in days. Sudden pressure drop after a repair = air intrusion. Re-check every suction-side connection with water pressure test.