A 1.5 HP well pump with a check valve on the inlet and a 6-zone FIMCO hydro-indexing valve loses prime, regains it, then loses it again—cycling throughout the run. The expert suspects a faulty check valve or a suction-side leak.
Start with the check valve—it’s the easiest to replace. Cut the PVC, install a new check valve with unions for future service. If the problem persists, pull the suction line to inspect the foot valve. In many cases, a new foot valve (stainless screen, weighted flapper) solves the cycling.
After any suction-line work, re-prime the pump fully (fill casing, vent air). The system should then hold prime through all zones.