4-valve system: single loud bang ONLY when last valve shuts off.
Water hammer. All valves running → last valve closes → sudden flow stop → pressure shock wave.
Any valve closing last would cause it. Not a valve defect.
Install water hammer arrestor (cylinder with spring/piston) on mainline. Absorbs shock wave. Available at plumbing/irrigation suppliers.