4-year-old pump, bladder tank, ~125 ft, whole house. Overheated, blew PVC fitting (pump to tank). Replaced, ran 1.5 days, blew again. Motor casing extremely hot, fitting soft/ballooned. Still pumps water.
"Apply pressure to it, air or water. Then apply soapy water to all the joints and watch for bubbles."
Overheating + blown fitting = pump running continuously (dead-head or near dead-head) due to switch failure or inability to build pressure due to air leak.