After a hard freeze cracked the above-ground PVC suction line from well to pump, the homeowner replaced the pipe but now the pump runs without moving water—it must be unplugged to stop. The system has a pressure tank on top. This is classic loss of prime.
The tank’s air charge should be 2 psi below the pump’s cut-in pressure (e.g., 28 psi for a 30/50 switch). If the bladder is ruptured, the tank will waterlog and cause rapid cycling—replace the tank.
Once primed and the foot valve holds, the system should run automatically. If the pump still cycles rapidly, the pressure switch or tank needs attention.