A Wilkins Zurn 950XL backflow preventer drips rapidly. User seeks a solution.
"Your backflow preventer is probably dirty (fouled) internally. It doesn't take much to make them leak." Matt suggests opening the test ports (small valves on the side) one at a time, then all, then in pairs while the system runs. "This isn't the 'official' service... but sometimes it works. By doing so, the internal valves open all the way and may flush the debris out."
"If this doesn't cure the problem the backflow needs to be opened and cleaned. You may want professional service for this. It has a few very strong springs inside and can be a bit dangerous and difficult to reinstall. The springs are under the 2 large caps which screw off."
Backflow preventers are safety devices; improper reassembly can compromise protection. Many jurisdictions require certified testers for repairs.
Winterizing Rain Jet RJC-6 System: Blow-Out Method
Identifying Purple PVC Pipe for Reclaimed Water Systems
Hunter EC Shows OFF After Power Outage: Disable Rain Off or Reset
Hunter SRC Controller Stuck on "OFF" After Winterization
Eliminating Pipe Vibration During Zone Transitions
Locating Buried Irrigation Lines Before Fence/Tree Installation
Rain Bird 9-Zone with Richdel Valves: Only Zone 6 Runs After Heavy Rain
Leaking Sprinkler Heads on a New Installation: Installation Defects to Check
Activating a Toro Vision I System in a New Home: Contact Installer for Start-Up Guidance
Sprinkler Zone Won't Shut Off: Valve Fault, Not Controller
Winterizing a Rain Bird Sprinkler System with Richdel Valves
Rain Bird "No Pwr" Error Persists After Transformer Swap
Spring Startup: Backflow Preventer Poppet Won't Seat
Backflow Preventer Sizing: 1" Valve on 3/4" Supply? Use 1" Throughout
Copyright © www.100flowers.win Botanic Garden All Rights Reserved