A 20-year-old, six-zone irrigation system with a 1 HP pump and a 45-foot-deep well suddenly delivers barely any flow after six months of inactivity. The pump runs but cannot build enough pressure to pop up the rotor heads. Priming and extended running did not help.
The foot valve (check valve) at the end of the suction line in the well is likely plugged with debris, sand, or mineral buildup. This restricts water entry into the pump, causing low flow and pressure.
If the foot valve is clear, the pump impeller or wear rings may be worn after two decades of service.