A homeowner turning on their sprinkler system in spring finds water gushing from under the top housing cover of the backflow preventer. No zones activate; water won't pass into the mainline. Good house pressure exists but stops at the backflow.
The backflow preventer likely froze over winter, cracking the internal poppet and seat assembly. This is common in climates with freezing temperatures if the device wasn't properly winterized (drained and/or blown out with compressed air).
Most jurisdictions require annual backflow testing by a certified tester. A rebuild kit fixes the mechanism, but the device must still pass a certified test to be legal for service.